5995504544 January 2008
Under the Counter Ice Maker
Service Manual
Models: EI15IM55GS, E15IM60GSS, and E15IM60GPS
Vista de página 0
1 2 3 4 5 6 ... 46 47

Resumo do Conteúdo

Página 1 - Service Manual

5995504544 January 2008Under the Counter Ice Maker Service ManualModels: EI15IM55GS, E15IM60GSS, and E15IM60GPS

Página 2 - Safe Servicing Practices

10Service Information25Échelon Electronic Control Quick GuidestnemmoCyalpsiDhcuoThcuoTksaTsdnoceS 01 dloHffO/nO1 oror2 Toggle LightsTouch once to get

Página 3 - Table of Contents

11Service InformationKeypad Options WARNINGElectrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious in

Página 4 - Installation

12Service InformationBlackout / Sabbath ModeThismodeallowsforobservationofholidaysonwhichlightscannotbeactivated.HoldtheLIGHTkeyfor1

Página 5

13Service InformationError Codes E1 Thermostor1isopen. E2 Thermistor1isshorted. E3 Maindoororbottomdrawerisopenlongerthan20minut

Página 6 - WARNING

14Service InformationThermistor TypesType 1 (Black)Resistanceat77°F=10,000ohms±5%Operatingrangeis185,000to650ohms.Resistancegoesdowna

Página 7 - General Instructions

15Service InformationFilter-Drier InstallationAnytimethesealedsystemisopenedandtherefrigerantchargeisremoved,theliquidlinelter-drier

Página 8

16Service InformationToachievetherequiredlevelsofevacuation,aproperlymaintainedtwostagevacuumpumpingoodconditionisrequired.Itisab

Página 9

17Service Information NOTEProcessvalvesarenottobeleftonthetubinginanyapplication,exceptthevalveonEMAServicedrierpart#53039

Página 10 - Service Information

18Service InformationHot TubeEvaporatorCondenserCompressor2 StageVacuum PumpHeatedChargingCylinderProcess TubeAdaptersFilter DrierPressureGaugeCompoun

Página 11

19Service InformationVerify Refrigerant Type In The SystemForexample,hosesthatwereusedforarefrigerationsystemoperatingonR-12maycontains

Página 12

2ATTENTION!!!This service manual is intended for use by persons having electrical and mechnicaltraining and a level of knowledge of these

Página 13

20Service InformationAttheearlieststageofdevelopmentworkonR-134a,testswerecarriedoutonadifferenttypeofsyntheticoilknownasPoly-Al

Página 14

21Service Information CAUTIONIf you use a vacuum pump with mineral oil to evacuate an R-134a system, it is ABSOLUTELY ESSENTIAL to have a shut-o

Página 15

22Service Information°F °C HFC-134a CFC-12 °F °C HFC-134a CFC-12-60 -51.1 21.8* 19.0* 55 12.8 51.1 52.0-55 -48.3 20.4* 17.3* 60 15.6 57.3 57.7-50 -45.

Página 16

23Service InformationInhalation ToxicityHFC-134aposesnoacuteorchronichazardwhenitishandledinaccordancewithDuPontrecommendationsandwhe

Página 17

24Service InformationAlways wearprotectiveclothingwhenthereisariskofexposuretoliquidHFC-134a.Wheresplashingispossible,always weareye

Página 18

25Service InformationIce Cube Thickness AdjustmentInterval - As RequiredIcethicknessadjustmentsaremadeusingthecontrolpanelasfollows:1.  To

Página 19

26Service InformationOperating Environmental/Climate Control RequirementsManyproductmodelsaredesignedtooperateinharshoutdoor/marineenvironme

Página 20

27Service Information36Model CLR2160OperationFigure 1HIGH PRESSURELOWPRESSURETRANSITIONAL PRESSUREIN CAPILLARY TUBEHLCLLCCCCCLLHHCLICEMAKER EVAPORATOR

Página 21

28Service InformationModel CLR216037Upon initial startup, this unit will enter mode number 5 which is a three-minute water fill regardless of the ther

Página 22

29Service Information38Model CLR2160WARMER and COLDER for five seconds. We’ll assume the display showed 38°F for this example. Go to service mode #24

Página 23

3Table of ContentsSafe Servicing Practices - All Appliances...2InstallationLeveling ...

Página 24

30Service InformationModel CLR216039Wiring DiagramIce Production RatesNOTE: These characteristics will vary depending on operating conditions, condens

Página 25

31Service Information40Model CLR2160Prepare PlumbingCAUTIONPlumbing installation must observe all state and local codes. All water and drain connectio

Página 26

32Service InformationModel CLR216041Figure 5Figure 6IMPORTANTIMPORTANTBefore installing your U-Line CLR2160 with factory- installed U-Line P60 pump, i

Página 27

33Service Information42Model CLR21609. Unplug unit power cord from electrical outlet.10. Reinstall back panel.To connect to drain:1. Attach the 5/8&qu

Página 28

34Service InformationModel CLR216043Figure 103. Your U-Line icemaker requires a drain connection. This unit can be purchased with or without a factory

Página 29

35Service Information44Model CLR2160front to back. For disposal connections an optional adapter may be required (included with the kit) to adapt from

Página 30

36Service Information46Model CLR2160Self-Cleaning Cycle InstructionsTo maintain operational efficiency, clean unit every six months. (Depending on wat

Página 31

37Parts InformationModel CLR216047CLR2160Figure 218 Parts SectionItem Description Figure Page2 INTERIOR, CLR2160 24 513 HINGE COMP 25 524 DOOR COM

Página 32

38Parts Information48Model CLR2160Figure 22ULIN_S_0032b_C2543111109876Model CLR216049Item Description Part Number1 THERMISTOR (quick connect white) 68

Página 33

39Parts Information50Model CLR2160Figure 23Item Description Part Number1 BACK PANEL 11964-022 BACK PANEL SCREWS 413423 SOLID HOLE COVER 421254 PERFORA

Página 34

4InstallationLevelingIt is extremely important that the unit is level for maximum protection.If it is not: • Doorsand/ordrawerswillnotworkprop

Página 35

40Parts InformationModel CLR216051Figure 24ULIN_S_0075_A1048256719311Item Description Part Number1 STAND PIPE 316192 FRONT COVER 118683 WELL NUT (incl

Página 36

41Parts Information52Model CLR2160Figure 25ULIN_S_0049a_AAccessory onlyThis is not aReplaceable part1716159131211141414321256131078Model CLR216053Item

Página 37 - Parts Information

42Parts Information54Model CLR2160Figure 26ULIN_S_0064b_A5 2 3 4 1 6 7 10 11 8 9 12 13 14 15 16 1718

Página 38

43Parts InformationModel CLR216055Figure 27Figure 26Figure 27ULIN-P60-00_A18 Item Description Part Number1 COMPRESSOR EMY70HER 70081-S2 PROCESS TUBE (

Página 39

44Parts Information56Model CLR2160Figure 28Item Description Part Number1 EVAPORATOR ASSEMBLY 2276-S2 HEAT EXCHANGER (included with 2276-S) 2725-S3 PRO

Página 40 - ULIN_S_0075_A

45Customer Call GuideConcern ResponseThe unit is not cold enough! (All models)Areyoufamiliarwiththefactorytemperaturespecicationsforyouruni

Página 41 - Figure 25

46Customer Call GuideConcern ResponseWhen I turn the unit on, all I get is water fill.Ouncetheunitisturnedon,therewillbeathreeminutewater

Página 43 - ULIN-P60-00_A

5Installation13Checking Door Alignment - Échelon ModelsThe unit’s door is aligned at the factory before shipment. However, its alignment could have be

Página 44 - ULIN_S_0077_A

6Installation / General Instructions Adjusting Door Alignment1.  Loosen(donotremove)topandbottomhingescrews(Figures 9 and 10).15Adjusting D

Página 45 - Customer Call Guide

7General Instructionsthecontrol,touchanykeyandthedegreesymbolwillbegintoashTo exit this mode: Ifusingsoftwareversion2.8,thismodewi

Página 46

8Service InformationService MenuEntertheServiceMenubyholdingUParrowandpressingLIGHTkeythreetimes.Selectoption1to27withtheupandd

Página 47

9Service Information E9 Thermister4openorshorted. E11 EEMemoryerror. P1 Pumpcircuitopen.AllerrorsorcombinationshowupasERalternati