14 1075WC
TROUBLESHOOTING GUIDE
DANGER
ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on
the unit until the main electrical power has been
disconnected.
PROBLEM POSSIBLE CAUSE REMEDY
Unit does not operate. No electrical supply. Plug unit in or check circuit breaker.
No interior light Loose or burned out bulb Tighten or replace bulb (See MAINTENANCE; LIGHT
BULB REPLACEMENT).
Light won’t go out when door is
closed.
Light on/off switch is turned to ON. Turn switch to OFF (see OPERATION).
Unit not cold enough. Light staying on. Adjust door (see MAINTENANCE, DOOR ALIGNMENT).
Door gasket not sealing properly. Adjust door (see MAINTENANCE, DOOR ALIGNMENT).
Dirty condenser coils Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).
Air flow to front grille blocked. Air flow must not be obstructed to front grille. (See
OPERATION).
High ambient air temperature or
exposure to direct sunlight.
Reposition unit.
Temperature not cold enough. Set control to a cooler setting (see OPERATION). Allow
24 hours for temperature to stabilize.
Unit is too cold. Control set too cold Set control to a warmer setting (See OPERATION). Allow
24 hours for temperature to stabilize.
The unit frosts up. High ambient temperatures or
humidity
Defrost unit manually (See MAINTENANCE;
DEFROSTING).
Door gasket not sealing. Door left
open.
Adjust door (See MAINTENANCE; DOOR ALIGNMENT).
Freezing product. Product touching evaporator in back
of unit.
Move product away from evaporator; make sure it is
not touching evaporator.